BOLT GUN STUNNING										Presence of VER
				PRE stun		POST stun				Absence of VER
				Light	Dark	Light	Dark		Amplitude quoate 	
				VERs in beta	VERs in beta	VERs in beta	VERs in beta		Light phase (max-min)	
	Values based on 37-60 s of measurements	Values based on 60-80 s of measurements		Max - Min	Max - Min	Max - Min	Max - Min		Dark phase (max-min)	
FISH	Amplitude light phase before stunning (mV)	Amplitude light phase after stunning (mV)		mV	mV	mV	mV		PRE stun	POST stun
1	0.001324	0.000269		0.001324	0.00036	0.000269	0.000281	→	3.6777777777777776	0.9572953736654803
2	0.002519	0.000204		0.002519	0.000536	0.000204	0.000344	→	4.699626865671641	0.5930232558139534
3	0.001959	0.000329		0.001959	0.000383	0.000329	0.000396	→	5.114882506527414	0.8308080808080808
4	0.01715	0.000663		0.01715	0.000761	0.000663	0.000803	→	22.536136662286463	0.825653798256538
5	0.002586	0.000615		0.002586	0.000672	0.000615	0.000619	→	3.848214285714286	0.9935379644588045
6	0.001211	0.00022		0.001211	0.000521	0.00022	0.000276	→	2.324376199616123	0.7971014492753624
										
										
VERs and ventilation were lost immediately upon bolt gun stunning and did not recover 										